| Applications
|
Electrode Range/Type
|
Electrode Cat No.
|
Solution Kit
|
Replacement Calibration Std
|
Replacement ISA
|
| Ammonia (NH3)
High Purity power station water, fish tanks, sea water, waste water, plating baths, air/stack gases, and biological samples
|
17,000 to 0.01 ppm
Gas Sensing
Single Junction
|
|
|
|
N/A
|
| Ammonium (NH4+)
Boiler feed water, natural water and fertilizers. User must supply cal standard.
|
18,000 to 0.01 ppm
Polymer Membrane
Double Junction
|
|
|
N/A
|
|
| Bromide (Br -)
Water, wine, soil, plant tissue, blood electrolytes and clinical analysis
|
79,000 to 0.4 ppm
Solid State
Double Junction
|
|
|
|
|
| Cadmium (Cd +2)
Plating Baths.
User must supply Calibration Standard
|
11,200 to 0.01 ppm
Solid State
Double Junction
|
|
|
N/A
|
|
| Calcium (Ca +2)
Water softeners, boiler feed water, drinking/mineral water, blood, clinical analysis and food.
|
40,000 to 4.4 ppm
Polymer Membrane
Double Junction
|
|
|
|
|
| Carbon Dioxide/Carbonate
Soft drinks, carbonated beverages, sine, beer, fermentation processes and bacteria cultures.
|
440 to 4.4 ppm
Gas Sensing
Single Junction
|
|
|
|
|
| Chloride (Cl -)
River/tap water, plant tissue, soils, boiler feed water, blood electrolytes, clinical analysis, sweat, urine, cement, plating baths and food samples.
|
35,000 to 1.8 ppm
Solid State
Double Junction
|
|
|
|
|
| Copper (Cu +2)
Plating baths and water
|
6350 to 0.00064 ppm
Solid State
Double Junction
|
|
|
|
|
| Cyanide (CN -)
Plating baths, waste water and plant tissue. User must supply calibration standard.
|
260 to 0.13 ppm
Solid State
Double Junction
|
|
N/A
|
N/A
|
|
| Fluoride (F -)
Drinking/Natural water, waste water, air/stack gas, acids, sea water minerals, soils, food, biological fluids, toothpaste, coal, soft drinks, bone.
|
Saturated to 0.02 ppm
Solid State
Double Junction
|
|
|
|
|
| Fluoroborate (BF4 -)
Plating baths (boron analysis)
|
10,8000 to 0.1 ppm
Polymer Membrane
Double Junction
|
|
|
|
|
| Iodide (I -)
Milk, feeds, plants and pharmaceuticals
|
127,000 to 0.006 ppm
Solid State
Double Junction
|
|
|
|
|
| Lead (Pb +2)
Plating Baths and organic compounds.
|
20,700 to 0.2 ppm
Solid State
Double Junction
|
|
|
|
|
| Nitrate (NO3 -)
Surface/drinking water, sewage effluent, soil extracts, fertilizers, plant tissue, meat, potatoes, spinach, beets and baby food.
|
62,000 to 0.5 ppm
Polymer Membrane
Double Junction
|
|
|
|
|
| Nitrogen Oxide (NOx)
Air and Stack gases
|
220 to 0.2 ppm
Gas Sensing
Single Junction
|
|
|
|
|
| Perclorate (ClO4)
Explosives and solid propellants
|
98,000 to 0.7 ppm
Polymer Membrane
Double Junction
|
|
|
|
|
| Potassium (K +)
Waste water, river/tap water, blood, clinical analysis, saliva, serum, fertilizers, soils and wines.
|
39,000 to 0.04 ppm
Polymer Membrane
Double Junction
|
|
|
|
|
| Silver/Sulfide (Ag +/S -2)
Sewage effluent, soils, sediments, plating baths and photographic fixing solutions. Supply sulfide soln.
|
107,900 to 0.01 ppm
Solid State
Double Junction
|
|
|
|
|
| Sodium (Na +)
Steam condensates in power plants, blood, clinical analysis, serum, wine, glass, seawater, swimming pools, fish farms and aquariums.
|
23,000 to 0.2 ppm
Glass Bulb
Double Junction
|
|
|
|
|
| Surfactant (X+, X-)
Detergents, dishwashing liquids, cleaning supplies and food products. For titration only.
|
12,000 to 1.0 ppm
Polymer Membrane
Double Junction
|
|
|
|
|
| Water Hardness (Ca +2 Mg +2)
Water softeners, boiler feed water, clinical analysis, drinking/mineral water, blood and food.
|
40,000 to 0.4 ppm
Polymer Membrane
Double Junction
|
|
|
|
|