713P Hydrostatic Pressure Flow Controller
|
| |
|
Quantity in Basket:
None
Code: 713P
Price: $2,430.00
|
| |
Non-standard
cables up to 1000 ft total available on special order - call for details.
Thread
connection available on pressure transmitter - call for details.
|
713P
Hydrostatic Pressure Flow Controller
by MJK
The MJK
713P flow controller is designed for installations where the water
is rough or the environment is foggy. The system is based upon a microprocessor-based
controller that works with MJK's rugged hydrostatic pressure sensors
for accurate level measurement. These pressure sensors work best in
applications where ultrasonic sensors are not acceptable.
|
|
|
Features:
- Rugged
hydrostatic pressure sensor.
- Measures
and indicates actual flow and average flow for the last hour, day,
and previous day.
- English
or metric measurement.
- Text
display for programming and reading of measurement values with all
indications in plain language (English or Spanish).
- 4 relays
for control of pumps, valves, motors, and alarms.
- Lead/lag
pump alteration.
- Serial
data output for PC communication.
|
|
|
|
SPECIFICATIONS
|
|
713P
Flow Controller
|
|
Hydrostatic
Level Transmitter
|
|
Measuring
Range
|
0
- 1 ft; 0 - 3 ft
|
Measuring
Range
|
0
- 1 ft; 0 - 3 ft
|
|
Temperature
Range
|
-20
to 65 °C (-5 to 150 °F)
|
Temperature
Range
|
-20
to 65 °C (-5 to 150 °F)
|
|
Voltage
Supply
|
110-120VAC,
power consumption 10W max.
|
Temperature
Drift
|
Less
than or equal to 0.005%
|
|
Accuracy
|
Less
than or equal to ± .2% of adjusted range
|
Accuracy
|
Less
than or equal to 0.5% FS
|
|
Digital
Outputs:
|
Terminal
6 - 17: Relay no. 1-4, max. 250V, max 4A resistive/max 100W inductive
load; selectable as alarm, counter, flow > 0 or sampler output
Terminal 19-20: Totalizer output (optocoupler), max 36V AC/DC,
50mA, one shot, programmable from 100ms to 10s
|
Cable:
|
2
x AWG 20, shielded, oil-resistant PVC insulation. Length 39ft, can be
extended to max 600 ohm loop resistance.
|
|
Analog
Outputs:
|
Terminal
21-22: (0)4-20mA, max 500 ohm loop resitance, galvanically isolated.
|
Materials
& Enclosure:
|
Diaphragm:
gold-plated ceramic; Housing: polypropylene, NEMA 6P, max 10ft submersion
|
|
Materials
& Enclosure:
|
Polystyrene
(housing and cover);
NEMA 4X
|
|
Approvals
|
UL-cUL
listed, file #194021 UL 508/c22: 2 No. 142-M1987
|
Approvals:
|
EN5081-1,
EN50082-1
|
|
Dimensions:
|
185
x 240 x 115 mm
|
Dimensions:
|
60mm
dia x 166 mm height
|
Check
out our flow
rate accessories!
|
|